节点文献
HPLC示差折光分析法测定乳糖醇的含量
Determination of lactitol by HPLC with refractive index detector
【摘要】 HPLC法测定乳糖醇的含量:采用Beckman碳水化合物柱,流动相为重蒸水,柱温90℃,示差折光检测器检测。最低检测限为10μg/ml(S/N=3),在0.25~4mg/ml的范围内呈良好的线性关系,r=0.9994.日内和日间相对标准差均小于3.0%。
【Abstract】 An HPLC method was used to measure lactitol. It was equipped with a refractive index detecor and a Beckman carbohydrate column. The column temperature was maintained at 90±0. 5 ℃ and the mobile phase was redistilled water. The results showed that the limit of detection was 10 μg/ml (S/N=3), the linear range was 0. 25~4 mg/ml (r = 0. 9994), and the precisions within a day or among d days all were less than 3. 0%.
- 【文献出处】 西北药学杂志 ,NORTHWEST PHARMACEUTICAL JOURNAL , 编辑部邮箱 ,1997年04期
- 【分类号】R927.2
- 【被引频次】10
- 【下载频次】171