节点文献
600MW 机组锅炉水冷壁大面积环向裂纹泄漏原因分析及治理对策
Analysis of Underlying Causes and Countermeasures for Dealing with Large Circumferential Cracks in a 600 MW Boiler Water Wall
【摘要】 作者在文献〔1〕〔2〕中对某电厂600MW机组锅炉水冷壁频繁出现大面积环向裂纹进行了失效分析,并对电化学腐蚀在疲劳裂纹萌生和扩展过程中的作用进行分析。本文在此基础上对环向裂纹形成的原因进行综合分析,并提出了治理措施和建议。
【Abstract】 The authors have made a failure analysis of the repeated emergence of large circumferential cracks in the 600 MW boiler water wall of a power station(see paper, in references)and investigated the role of electrochemical corrosion in the formation and propagation of fatigue cracks On the basis of the above a comprehensive analysis is given of the causation of such circumferential fissures with pertinent countermeasures being proposed
【关键词】 锅炉;
水冷壁;
环向裂纹;
分析;
对策;
【Key words】 boiler; water wall; circumferential crack; analysis; countermeasure;
【Key words】 boiler; water wall; circumferential crack; analysis; countermeasure;
- 【文献出处】 热能动力工程 ,JOURNAL OF ENGINEERING FOR THERMAL ENERGY AND POWER , 编辑部邮箱 ,1997年04期
- 【分类号】TK225
- 【被引频次】2
- 【下载频次】84