节点文献
流动注射化学发光测维生素B12
Determination of vitamin B12 in injection and piu by chemiluminesence-flow-injection analysis
【摘要】 本文用镀锌粒作成还原柱在线还原维生素 B12,使其催化 H2O2氧化 Luminol 产生化学发光,实现 VB12在线检测。方法的检出限为3.1×10-10g/ml,RSD=2.0%(n=7,C=1×10-7g/ml)。用于针剂、片剂 VB12测定,结果满意。
【Abstract】 A novel and effective ness in the site reductor minicollumn made of zinc coated with copper was established to reduce vitamin B12for the Luminol-H2O2-Vitamin B12.The linear range of determination was 1.0×10-9~1.0 ×10-6g/ml.The relative standard deviation(n=11)was 2.0%.The detection limit was 3.1×10-10g/ml,and the determination results for in injection and pill samples were in good agreement with those of standard method.The reduction collumn can be used for 2000 at least.
- 【文献出处】 佳木斯医学院学报 , 编辑部邮箱 ,1997年06期
- 【分类号】O657.3
- 【被引频次】4
- 【下载频次】44