节点文献

电化学发光法测定人发中的铜

Determination of Copper in Hair by Electrochemiluminescence

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘华俊聂峰李辉升

【Author】 Liu Huajun; Nie Feng;Li Huisheng(Department of Chemistry, Xiangyang Teachers College,Xiangfan,Hubei,441053)(Department of Chemistry, Hanzhong Teachers College,Hanzhong,Shaanxi,723000)

【机构】 襄阳师专化学系!湖北襄樊441053汉中师院化学系!陕西汉中723000

【摘要】 采用阳极溶出伏安法分离富集铜,并选用盐酸羟胺作发光试剂,结合流动注射技术建立了一种新的电化学发光测定铜的分析方法.该法选择性好、灵敏度高.其线性范围是6.0×10-7~4.0×10-10kg/L铜,RSD是3.2%(n=11;Cs=1.0×10-7kg/L),检测限是1.0×10-10kg/L铜,可用于人发中铜的测定.

【Abstract】 A new electrochemiluminescence method is developed by combining anodic stripping voltammetry and chemiluminescence. This method has a fine selectirity.The linear range is 4.0 ×10-10 ~ 6.0 ×10-7 kg/L Cu2+, the detection limit is 1.0×10-10kg/L Cu2+, the relative standard deviation is 3.2% for 1.0×10-7 kg/L Cu2+ (n = 11). The method has been applied successfully to the determination of copper in hair.

【关键词】 电化学发光流动注射盐酸羟胺
【Key words】 Copperelectrochemiluminescencehydrochlorichydroxy amine
  • 【文献出处】 汉中师范学院学报(自然科学) ,Journal of Hanzhong Teachers College , 编辑部邮箱 ,1997年06期
  • 【分类号】R446
  • 【被引频次】1
  • 【下载频次】45
节点文献中: 

本文链接的文献网络图示:

本文的引文网络