节点文献

痕量铁的在线监测研究

STUDY ON DETERMINATION OF TRACE IRON(Ⅲ)ON LINE

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈浩汉

【Author】 Chen Haohan (Department of Chemistry, Hubei Education College, Wuhan, 430060)

【机构】 湖北教育学院化学系

【摘要】 根据在邻菲罗啉的活化下Fe3+对KIO4氧化罗丹明B褪色的催化作用,利用流动注射技术,建立了一个痕量铁的在线监测的新方法.该方法Fe3+的浓度在0~8×10-5g/L和8×10-5~2.8×10-4g/L范围内分段与褪色效应呈良好线性相关,检出限为:1×10-7g/LFe3+(3δ);RSD≤1.6%(c=5×10-5g/L,n=11).利用该方法对水样中铁进行在线监测,效果满意

【Abstract】 A new FIACatalytic Kinetic Spectrophotometric method for the determination of trace iron(Ⅲ) on line is described. The method is based on catalytic effect of iron(Ⅲ) on the oxidation of Rhodamine B by KIO 4 in the presence of OPhenanthroline as an activator. The linear range of the concentration for iron ion(Ⅲ) related to fading reaction is from O to 8×10 -5 g/L and from 8×10 -5 g/L to 2 8×10 -4 g/L. The detection limit (3σ) for iron (Ⅲ) is 1 0×10 -7 g/L. The method has been used to the determination of trace iron(Ⅲ) in water samples on line with satisfactory results.

  • 【文献出处】 湖北大学学报(自然科学版) ,JOURNAL OF HUBEI UNIVERSITY(NATURAL SCIENCE EDITION) , 编辑部邮箱 ,1997年02期
  • 【分类号】O657
  • 【被引频次】2
  • 【下载频次】26
节点文献中: 

本文链接的文献网络图示:

本文的引文网络