节点文献

α型硅钼蓝法测铝中硅的研讨

A Study on the α-Silcon Molybdenum Blue Method for the Determination of Silicon in Aluminium

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 黎淑平

【Author】 LI Shuping(South China University of Technology, Guang zhou 510641, P. R. China)

【机构】 华南理工大学测试中心!广州市510641

【摘要】 实验考察了影响硅钼蓝法结果重视性及准确性的因素;比较了α型硅钢蓝及β型硅钼蓝的异同、特点;提出了利用α型硅钼蓝法线性范围宽、稳定性好的优点,同时测定铸铝中高含量硅和铝合金中低含量硅的分析方法。

【Abstract】 The factors effecting the accuracy of silicon molybdenum blue method were studied, the wand β-silicon molybdenum blue methods were compared. It was suggested to use the α-rmethod because of its wider linear range and better stability. an analytical method was established to determine the high alumininm content in casting aluminium and the low aluminium content in aluminium alloy.

  • 【文献出处】 光谱实验室 ,CHINESE JOURNAL OF SPECTROSCOPY LABORATORY , 编辑部邮箱 ,1997年01期
  • 【分类号】O657.3