节点文献
X-52管线钢连铸坯高温变形试样中碳、氮化物的析出和钢的高温延性
CARBIDE AND NITRIDE PRECIPITATION AND HOT DUCTILITY OF X-52 LINE-PIPE STEEL CC SLAB
【摘要】 测试了3X-52钢连铸坯试洋的高温延性。变形试样中主要有三类碳、氮化物析出:高温下析出的块状粗大 TiN 析出物;950~900℃沿晶界和在晶粒基体内部析出的微细动态析出产物;依附在 TiN 颗粒上生成的复合析出物。与不含钛的含铌钢相比,X-52钢试样在850℃~Ar3温度之间没有出现进一步的延性降低,γ→P转变温度的提高,减轻了其在第Ⅲ脆性温度区的脆性程度。
【Abstract】 Hot ductility of the X-52 line-pipe steel CC slab was measured.Three types of precipitates were found in the fractured specimens.One is the block-shaped coarse TiN particles precipitated at high temperature.Another is fine dynamic precipitation products precipitated at 950~900℃.The third type is the coexisted precipitates formed by fine Nb precipitates nucleating and growing on TiN particles.Comparing with Nb-containing steel which contains no Ti,there is no ductility drop for X-52 steel at temperature between 850 ℃ and Ar3,and its transfer temperature from γ to P is higher,thus ductility of the steel is improved in the low ductility temperature region Ⅲ.
【Key words】 Nb-Ti micro-alloying steel,; CC slab,; hot ductility,; carbide,; nitride; precipitation;
- 【文献出处】 钢铁 ,Iron & Steel , 编辑部邮箱 ,1997年11期
- 【分类号】TF777
- 【被引频次】2
- 【下载频次】129