节点文献

螯合树脂静态富集/电热蒸发(ETV)-ICP-AES测定铂族元素Pt、Pd和Os

Static Preconcentration of Platinum Group Metals and Their Determination by ChelatingResin and Electrothermal Vaporization Inductively Coupled Plasma Atomic Emission Spectrometry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 秦永超江祖成白帆曾云鹗

【Author】 Qin Yongchao,Jiang Zucheng ,Bai Fan and Zeng Yun′e ,(Department of Chemistry,Wuhan University,Wuhan 430072),Fenxi Shiyanshi

【机构】 武汉大学化学系

【摘要】 用含氮、硫功能团的螯合树脂YPA4进行静态吸附,含待测元素的浓缩物制成悬浮体,采用悬浮体进样/电热蒸发等离子体原子发射光谱(ETV-ICP-AES)直接测定。方法的检出限分别为0.5、0.7和4.0ng/mL(对Pt、Pd和Os),相对标准偏差分别为2.6%、4.7%和3.8%(n=10,Pt∶2.0mg/L,Pd∶2.0mg/L,Os∶5.0mg/L)。应用本法对地质标样进行了分析,测定值与标准值基本吻合。

【Abstract】 In this paper ,a rapid method using static adsorption by chelating YPA 4 resin preconcentration and slurry sampling/electrothermal vaporization inductively coupled plasma atomic emission spectrometry has been developed for the determination of platinum group elements Pt,Pd and Os.The detetion limits of Pt,Pd and Os are 0.5,0.7 and 4.0μg/mL,and the RSD are 2.6%,4.7% and 3.8%( n =10,Pt∶2.0mg/L,Pd∶2.0mg/L,Os∶5.0mg/L),respectively.The proposed method has been applied to determine trace Pt,Pd and Os in geological reference materials,and the determined values were in good agreement with the certified ones.

【基金】 国家自然科学基金,国家教委博士点基金
  • 【文献出处】 分析试验室 ,ANALYTICAL LABORATORY , 编辑部邮箱 ,1997年04期
  • 【分类号】O657.3
  • 【被引频次】16
  • 【下载频次】50
节点文献中: 

本文链接的文献网络图示:

本文的引文网络