3000 m~3/h 烟气脱硫试验系统的设计与运行
Design and operation of system of SO 2 removal from flue gas by pulse corona discharge
【摘要】 在基础性研究工作的基础上,进行了3000m3/h脉冲放电等离子体烟气脱硫的小型工业性试验.给出了该试验系统的设计和运行结果;在总能耗小于5W·h/m3条件下,SO2脱除率为75%~80%.该试验结果证实了脉冲放电等离子体烟气脱硫技术的可行性.
【Abstract】 On the basis of the fundamental research, an industrial pilot with the flow rate of 3 000 m 3/h has been conducted. The results of the design and operation of the system have been obtained. The results show that the removal efficiency of SO 2 is up to 75% 80% at the energy consumption rate of 5 W·h/m 3. It is also certain that the industrial application of this technology will be feasible.
【基金】 “八五”国家科技攻关项目
- 【文献出处】 大连理工大学学报 ,JOURNAL OF DALIAN UNIVERSITY OF TECHNOLOGY , 编辑部邮箱 ,1997年05期
- 【分类号】X511
- 【被引频次】46
- 【下载频次】125