节点文献

霓虹灯与漏磁变压器的合理匹配

The reasonable matching between Neon and leakage flux transformer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 林跃强李北川兰国亚

【Author】 Lin Yueqiang; Li Beichuan;Lan Guoya(Dept.of Phys.Southwest Ching Normal University,Chongqing 630715)

【机构】 西南师范大学物理系

【摘要】 测试了漏磁变压器在连接不同长度的霓虹灯管时的效率,确定出变压器的最佳工作效率的条件;为提高霓虹灯安装电路的功率因数,测量了在变压器与灯管匹配较佳状态下,输入回路并联不同容量的电容,对电路功率因数的影响.并给出了漏磁变压器与霓虹灯管合理匹配的技术参数.

【Abstract】 The working efficiency of the leakase flux transformer was tested When it is connected with Neons of different lengths. And the conditions that the transformer works most efficiently are ascertained.In order to imptove the power fsctors of the network of the Neon,the power faCtors I were also tested when the Neon matched well with the transformer under conditions whprt the input circuit was in peallel with various capecitors of different capacity,and the technical factors of the reasonable mptching between Neon and teakape flux transformer are proposed.

【关键词】 霓虹灯漏磁变压器匹配
【Key words】 Neonleakage flux transformerintegration
  • 【文献出处】 西南师范大学学报(自然科学版) ,JOURNALOF SOUTHWEST CHINA NORMAL UNIVERSITY(NATURAL SCIENCE) , 编辑部邮箱 ,1996年01期
  • 【分类号】TM923.3
  • 【被引频次】2
  • 【下载频次】59