人类免疫缺陷病毒抗体EIA检测试剂质控参考品的建立

Establishment of Quality Control Reference of EIA Reagent for Anti-HIV Detection

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王兵陆明宋爱京尹红章李德富

【Author】 Wang Bing; Liu Ming; Song Aijing et al (National Institute for the Control of Pharmaceutical and BioloArical Products, Beijing 100050)

【机构】 中国药品生物制品检定所!北京100050

【摘要】 以国际抗-HIV质控参考品为参比,用亚塔、阿克苏、UBI、普生、万芬等国内外试剂对41份执-HIV阳性和阴性人血浆进行筛查,并进一步以免疫印迹法确证,建立了我国第一代抗-HIV检测试剂质控参考品,其中包括阳性、阴性、灵敏度和精密性参考品。用本品对91批次国产试剂进行检测并与国外试剂进行对比,证明有较好的分辨力。在此基础上制定出我国抗-HIV检测试剂质量标准,此标准及参考品已获国家批准。

【Abstract】 The first quality control references of EIA reagent for anti-HIV detection, including postivity, negativity, sensitivity and precision references, were established by screening 41 samples of anti-HIV positive or negative human plasma by domestic and imported reagents, using International anti-HIV Quallty Control Reference as standard. Confirmatory tests were done by Western Blot. 91 lots of domestic reagents were detected by the reference and compared with imported reagents. The reference showed good resolving capability. Anti-HIV detection reagent quality standard was estabitished on the basis of this study and approved by the National Authority as well as reference,

【关键词】 HIVELISA参考品
【Key words】 HIV ELISA Reference
  • 【文献出处】 中国生物制品学杂志 ,Chinese Journal of Biologicals , 编辑部邮箱 ,1996年01期
  • 【分类号】R446.62
  • 【被引频次】7
  • 【下载频次】68