节点文献

对输电线击杆率的探讨

Discussion on Rate of Lightning Striking against Poles of Transmission Lines

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘明光颜怀梁

【Author】 Liu Mingguang Yan Huailiang(Sichuan Institute of Technology,Chengdu 611744)

【机构】 四川工业学院四川工业学院 611744611744

【摘要】 输电线的击杆率直接影响到线路雷击跳闸率计算.击杆率不仅与地形、地势、杆塔的高度、结构有关.还与雷电流的幅值、概率有关.针对《规程》推荐的击杆率,采用电气几何模型的原理,探讨了线路平均击杆率.

【Abstract】 For transmission lines,the rate of lightning striking against poles directly affects the calculation of lightning trip-out rate.The former has not only relations to topographic features, height and structure of poles or towers but also to amplitude and probability of lightning-current. According to the rate recommended by the"code",the mean rate of lightning striking against poles of transmission lines is discussed with an electrogeometric model.

  • 【文献出处】 四川电力技术 ,Sichuan Electric Power Technology , 编辑部邮箱 ,1996年01期
  • 【分类号】TM754;TM86
  • 【被引频次】3
  • 【下载频次】50