节点文献
流动电流检测器取样流量的分析与研究
Research on Sample Flow of Streaming Current Detector
【摘要】 本文对流动电流检测器自清洗方式的取样流量进行了分析与研究.理论分析与实验都证明,取样流量的大小直接影响检测器的检测灵敏特性.实验结果表明,最佳取样流量范围为4~6L/min.
【Abstract】 Sample flow of Streaming Current Detector(SCD) cleaned by itself was studied in this paper. It was verified by theoritical analysis and experiment that the amount of sample now directly affected the signal of the SCD. As the result of the experiment, the optimum range of flow was 4 ̄6L/min.
【关键词】 给水处理;
检测器;
流动电流;
取样流量;
混凝;
【Key words】 feed water treament; detection units; streaming current; sample flow; coagulant;
【Key words】 feed water treament; detection units; streaming current; sample flow; coagulant;
【基金】 国家八·五攻关项目
- 【文献出处】 哈尔滨建筑大学学报 ,JOURNAL OF HARBIN UNIVERSITY OF CIVIL ENGINEERING AND ARCHITECTURE , 编辑部邮箱 ,1996年04期