管式双级空气予热器不同连结方式温差场不均匀性分析

Analysis of Uniformity of Temperature Difference Field for Two-stage Tubular Air Preheater With Differential Linkage Methods

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李淑兰陈冀九杨沫

【Author】 Li Shulan (Power Engineering Department,Northeast China Institute of Electric Power Engineering,Jilin City 132012) Chen Jijiu (Automatic Control Department Northeast China Institute of Electric Power Engineering,Jilin City 132012) Yang Mo (Powe

【机构】 东北电力学院动力工程系

【摘要】 对管式双级空气预热器上、下两级间采取不同连结方式引起传热温差场的差异,及对换热效果所产生的影响进行了分析,得出了从传热及热力学完善性考虑时,Z型连结优于C型连结的结论

【Abstract】 Based on the consideration of temperature different field caused by linkage style of two-stage tubular air heater,the paper analyzes the results of Heat transfer from Heat transfer and Thermodynamics perfect,and points out that Z-type arrangement is more superior than C-type.

  • 【文献出处】 东北电力学院学报 ,JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING , 编辑部邮箱 ,1996年03期