288例纤支镜检患者连续心电血氧监测
CONSECUTIVE OBSERVATION OF ELECTROCARDIOGRAM AND SaO2 TO 288 PATIENTS UNDERGOING FIBEROPTIC BRONCHOSCOPY
【摘要】 本文报道了288例14~86岁患者纤支镜检查前、中、后的连续血氧饱和度(SaO2)及心电监测结果。术前平均SaO2为97.17%。检查组术中平均降低2.09%,术后5分钟较术前降低1.7%。治疗组术中SaO2平均降低2.43%,术后5分钟较术前降低3.43%。术中心电图改变以窦性心动过速为主,占62%,原心电图不正常者术中心律失常加重为7%,原无心律失常者术中心律失常出现率为1.O%。由于纤支镜检术中抽查血气不便,我们认为无创的血氧饱和度、心电动态监测不失为一简单易行,可靠的监测手段。
【Abstract】 In this article,we discuss the results obtained from consecutive observations of electrocardiogram and SaO2 saturation based on 288 aged of patients were patients before,during and after diagnostic Fiberoptic Bronchoscope. The ages of patients were 14~86 years old Among the examined group,the average SaO2 of subjects before diagnosis is 97. 17%;during the diagnosis the SaO2 of subjects decrease 2. 09%;five minutes after examinations the SaO2 of subjects is 1.7% lower than that before the examinations. Among the treatment group ,the average SaO2 decreases 2.43%. Five mintes after examination, it is 3. 43% lower than that before examinations. During the examination, the changes of electrocardiograms are mainly caused by sino-auricular tachycadia which is 62% of the whole changes. Seven per sent of subjects whose electrocardiograms are abnormal undergoes worse abnormal rhythm of heart.1.0% of normal-electrocardiogram-patients is reported abnormal heart-beating. Since it is inconvenient to evaluate(test) the hemopneumo,we believe that motive non injury observation of electrocardiogram and SaO2 is a simple and reliable testing method.
【Key words】 Fiberoptic bronchoscopy; Oxyhemo stauration; Heart rate; Arrhythmial;
- 【文献出处】 内镜 , 编辑部邮箱 ,1995年04期
- 【分类号】R562.06
- 【被引频次】2