节点文献
自聚焦透镜光斑直径、分辨率测试研究
RESEARCH ON THE MEASUREMENT OF GEIN LENS FOCUSED SPOT
【摘要】 通过显微镜放大、CCD图像接收采集、计算机数据处理技术来测量自聚焦透镜(GRIN透镜)光斑直径、分辨率。重点对误差进行分析。通过对样品520-025-083的测试,表明该系统光斑直径、分辨率测试不确定度优于±0.1μm及1%,与误差分析相吻合。
【Abstract】 The measurement of GRIN lens focused spot diameter and resolution is made. The measuring error is analyzed. It is shown that system measuring uncertainty is better than ± 0. 1μm and ± 1 % by measuring the Sample 520--025--083. The result is good agreement with the error analysis.
- 【文献出处】 应用光学 ,JOURNAL OF APPLIED OPTICS , 编辑部邮箱 ,1995年06期
- 【分类号】TH74
- 【被引频次】7
- 【下载频次】372