节点文献
核供热堆失水事故模拟实验研究
Experimental simulation on LOCA of a nuclear heating reactor
【摘要】 叙述了位于核供热堆堆芯上方注硼管位置的中小尺寸管道破裂引起的小破口失水事故实验研究。在核供热堆热工水力学模拟实验回路HRTL-5上,对停堆后堆内有剩余功率的小破口失水事故进行了模拟实验,给出了小破口失水事故发生后,系统压力、温度、堆芯元件壁温、堆内冷却剂排放量、液位、空泡份额等重要参数的变化曲线,以及对低温堆安全性的影响。
【Abstract】 An experiment of a small break of boron injection pipe above reactor core is described in this paper. The experiment was carried out on the thermohydraulic test system HRTL-5 for the nuclear heating reactor. The system pressure, temperature, the wall temperature of core, the liquid level, the void fraction and the discharged coolant mass etc in the test were studied under the conditions that there is residual power after the reactor shutdown. The effect on nuclear heating reactor safety is given in this paper.
【关键词】 失水事故;
核供热堆;
固有安全性;
【Key words】 LOCA(loss of coolant accident); nuclear heating reactors; inherent safety;
【Key words】 LOCA(loss of coolant accident); nuclear heating reactors; inherent safety;
- 【文献出处】 清华大学学报(自然科学版) ,Journal of Tsinghua University(Science and Technology) , 编辑部邮箱 ,1995年06期
- 【分类号】TL364
- 【被引频次】5
- 【下载频次】180