流动注射在线萃取-火焰原子吸收光谱法测定明胶中的微量Fe和Cu
DETERMINATION OF TRACE IRON AND COPPER IN GELATIN USING FAAS WITH FLOW INJECTION EXTRACTION SYSTEM
【摘要】 本文采用氧化水解制样及流动注射在线萃取火焰原子吸收光谱法,测定明胶中微量Fe和Cu,解决了水解法制样测定结果偏低和不能直接测定低含量样品的问题。本方法测定Fe和Cu的灵敏度分别提高了14.5倍和17.6倍,分析速度达36次/h,Fe和Cu的回收率分别在90.8-110.5%和87.5~107.0%之间,测定精密度分别为4.53%和4.26%。
【Abstract】 By oxidizing and hydrolyzing gelatin, trace amounts of iron and copper in gelatin were determined by FAAS with flow injection analysis technology of on-line extraction. Comparing with the hydrolyed gelatin method, our methed can not only gain better accuracy but also directly determine the low iron and copper content in gelatin.The sensitivity of determination increases 14. 5 times for Fe and 17. 6 for Cu,the recovery range is from 90. 8% to 110. 5% for Fe and 87. 5% to 107. 0% for Cu, and R. S. D.is better than 4. 53% for Fe and 4. 26% for Cu respectively. The sampling frequancy can achieve 36N/h..
【Key words】 Gelatin; Flow injection extraction; FAAS; Fe; Cu;
- 【文献出处】 光谱学与光谱分析 ,SPECTROSCOPY AND SPECTRAL ANALYSIS , 编辑部邮箱 ,1995年04期
- 【分类号】TQ572.22
- 【被引频次】8