P507萃淋树脂分离-火花源质谱法测定高纯Gd2O3中痕量稀土杂质

P507Extraction Chromatographic Separation Spark Source Mass Spctrometric Determination of 14 Rare Earths Impurities in High Purity Gadolinium Oxide

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王子树隋喜云牛娜梁玉军

【Author】 Wang Zishu;Sui Xiyun;Niu Na;Liang Yujun (Changchun Institue of Applied Chemistry,Chinese Academy of Sciences,Changchun 130022,China)

【机构】 中国科学院长春应用化学研究所

【摘要】 本文采用萃取色谱法,以P507萃淋树脂为固定相,以HCl-NH4Cl体系为洗脱液,研究了99.999%~99.9999%高纯Gd2O3中稀土杂质和Gd基体的分离方法,并选择了富集方法和火花源质谱测定条件,达到了纯度为99.9999%的高纯Gd2O3的分析测定要求

【Abstract】 The separation of rare earth impurities in high purity gadolinium oxide have been carried out with 2-ethylhexyl hydrogen- 2-ethylhexyl phoshonate (P507) extraction chromatography ; hydrochloric acid-ammonium chloride serves as eluant. The method of preconcentration and the determination conditions of spark source mass spectrometry have been selected. The measured purity of gadolinium oxide is up to 99.9999 %.

  • 【文献出处】 质谱学报 ,JOURNAL OF CHINESE MASS SPECTROMETRY SOCIETY , 编辑部邮箱 ,1994年03期
  • 【分类号】O657.63
  • 【被引频次】5