节点文献
复方硼砂溶液和苯酚消毒液中苯酚含量的紫外测定法
Determination of phenol in compound borax solution and phenol solution for disinfection by UV-spectrophotometry
【摘要】 本文采用紫外分光光度法测定复方硼砂溶液和苯酚消毒液中苯酚的含量。操作简便、快速,结果准确。测定波长为287nm,其平均回收率分别为100.4%(cv=0.81%)和99.77%(CV=0.34%)。
【Abstract】 UV-spectrophotometric method was used for the determination of phenol in compound borax solution and phenol solu-tion for disinfection. The method was simple, rapid and accurate,The wavelength used was 287nm,the average recovery was100.4%(RSD=0. 81%)and 99.8%(RSD=0. 34%)respectively.
- 【文献出处】 中国医院药学杂志 ,CHINESE JOURNAL OF HOSPITAL PHARMACY , 编辑部邮箱 ,1994年09期
- 【分类号】R927.2
- 【被引频次】3
- 【下载频次】71