节点文献
过氧化氢-甲基红体系催化分光光度法测定油品中的痕量铁
Determination of Trace Iron in Petroleum Products by Catalytic Spectrophotometry of Hydrogen Peroxide-Methyl Red System
【摘要】 用过氧化氢-甲基红体系催化分光光度法测定油品中的痕量铁,建立了轻油消化的操作方法。轻、重油品分别经消化、灰化后可直接测定。摩尔吸收系数为5.8×10 ̄5L(cm·mol) ̄-1,最低检测限为0.05μg/25ml,加标回收率为99.3%-102.5%。该法不受其他微量元素的干扰,操作简单,选择性好,灵敏度高。
【Abstract】 The method is based on the principle that Fe(Ⅲ)can catalyze the decolorizing reactionwhich results from the oxidation of methyl red by hydrogen peroxide in dilute H2SO4nedium.Digestion conditions of light petroleum products are inspected.Light or heavyietroleum products are directly determined after digestion or ashing.The molar absorptivityis 5.8 × l0 ̄5L·cm ̄-1·mol ̄-1,with detection limit of 0.05μg/25ml and recovery of 99.3%-102.5%。The method has been used for determining trace iron in petroleum products withsatisfactory resuIts。
- 【文献出处】 石油化工 ,PETROCHEMICAL TECHNOLOGY , 编辑部邮箱 ,1994年10期
- 【分类号】TE622.13
- 【被引频次】6
- 【下载频次】98