铝-酸性铬蓝K荧光光度法测定微量铝的研究
Aluminium-Acid Chrome Blue KFluorimetric Method for the Determination of Microamount of Aluminium
【摘要】 研究了酸性铬蓝K(ACBK)荧光光度法测定微量铝的反应。A3+与ACBK形成络合物的荧光强度与铝的含量在1×10-8~8×10-6mol/L范围内呈现良好的线性关系,检测限为4.8×10-9mol/L,对4×10-8mol/L铝重复11次检测其相对标准偏差为4.8%。成功地用于人发及钢样中铝含量的测定。
【Abstract】 A fluorimetric method for the determination of trace aluminium with Al3+-acid chrome blue K(ACBK) comple× is established. The e×citation and emission wavelengths are 520 and 593 nm. The linear range of this method is 1×10-8×10-6mol/L for aluminium. The detection limit is 4. 8×10-9mol/L. The RSD is 4. 8% (11 measurement to 4 × 10-8 mol/L A13+). The method has been used to determine aluminium in hair and steel samples.
- 【文献出处】 分析化学 ,Chinese Journal of Analytieal Chemistry , 编辑部邮箱 ,1994年06期
- 【分类号】O657.3
- 【被引频次】11
- 【下载频次】99