节点文献

离子色谱法(IC)测定高放废液中的Na~+,K~+离子

DETERMINATION OF Na~+ AND K~+ IONS IN THE HIGH-LEVEL LIQUID WASTE BY ION CHROMATOGRAPHY (IC)

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈连仲马桂兰

【Author】 CHEN LIANZHONG MA GUILAN (China Institute of Atomic Energy, P. O. Box 275. Beijing. 102413)

【机构】 中国原子能科学研究院中国原子能科学研究院 北京 102413北京 102413

【摘要】 应用离子色谱法测定高放废液中的Na~+和K~+离子。先以EDTA螯合树脂预处理柱,除去废液中的过渡金属和重金属离子,再用高效低容量离子交换树脂单柱离子色谱法分析测定Na~+、K~+离子。当Na~+和K~+离子含量为μg/ml水平时,方法精度好于5%。

【Abstract】 The determination of Na+ and K+ ions in the high-level liquid waste is investigated using ion chromatography, In order to protect the low capacity ion exchange resin in single column IC and remove the transition metal as well as other heavy metal ions that are contained in liquid waste, the pretreatment column with EDTA chelating resin is used. Those impurity metal ions are strongly absorbed by EDTA chelating resin and 100% of Na+ and K+ ions in the solution are eluated. The ability of the decontamination of EDTA chelating resin is satisfactory. The sample of the high-level liquid waste is dilluted appropriately, then an aliquot of the sample is passed through the pretreatment column with EDTA chelating resin, the eluate is analysed by single column ion chromatography. The precision of this method is better than 5% for the determination of Na+ and K+ ions (at μg·ml-1level)

  • 【文献出处】 原子能科学技术 ,Atomic Energy Science and Technology , 编辑部邮箱 ,1992年05期