【摘要】 讨论了条带式热管结构参数对传热性能的影响,实验确定了蒸发段管径、冷凝段换热面积及热管充液量等参数的适宜值,并给出了条带式热管平板太阳能热水器的热性能测试结果。
【Abstract】 The experimental study, analysis and discussion are conducted on the effect of the heat transfer characteristics of the SUNSTRIP fin-tube the heat pipe with variable structure parameters.Some useful results, such as the suitable values of the evaporator section diameter, the heat exchange area of the condenser section and the filling quantity of the heat pipe, are obtained.The experimental results of tests on thermal performance of the heat pipe flat plate solar water heater, with SUNSTRIP fin-tube heat pipes developed above, are given.
【关键词】 条带式热管;
传热性能;
太阳能热水器;
【Key words】 fin-tube heat pipe; heat transfer charateristics; solar water heater;