5MW低功率堆自动棒逻辑系统的多重联锁与检查
The Multi-interlock and Check of Logical System for 5MW Low Power Reactor Automatic Rod
【摘要】 5MW低功率堆(5MW LPR)自动棒逻辑系统采用了多重联锁与手动在役检查,提高了逻辑系统的可靠性和安全性。文中介绍了逻辑系统的设计特点及功能。
【Abstract】 The safety and reliability of the logical syatem for 5MW LPRautomatic rod are improved,because of using multi-interlock andmanual check on line.The design character and function of thelogical system are introduced in this paper.
【关键词】 5MW低功率堆;
多重联锁;
手动在线检查;
【Key words】 5MW Low Power Reactor; Multi-interlock; Manual check on line;
【Key words】 5MW Low Power Reactor; Multi-interlock; Manual check on line;
- 【文献出处】 核动力工程 ,Nuclear Power Engineering , 编辑部邮箱 ,1992年06期
- 【下载频次】16