节点文献

内直筋散热器钢管的冷拔试验

EXPERIMENTS ON COLD-DRAWING OF INTERNAL STRAIGHT-RIBBED STEEL PIPES FOR HEAT-EXCHANGER

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 姜正义杨贵平解春蓉王占林崔振武

【Author】 Jiang Zhengyi Yang Guiping Xie Chunrong(Northeast University of Technology) Wang Zhanlin Cui zhenwu(Panshi Seamless Steel Tube Plant)

【机构】 东北工学院东北工学院磐石无缝钢管厂

【摘要】 冷拔内直筋散热器钢管的难点是在拔制过程中凸筋高度充填的同时伴随着凸筋被拉缩。本文通过试验,分析了筋底壁厚压下率(ε%),壁径比(δ0/D0)、齿高比(K)及摩擦条件诸因素对凸筋高度充填和凸筋拉缩的影响及它们之间的关系。

【Abstract】 The key point of cold-drawing of internal straight-ribbed steel tubes for heat-exchanger lies in the fact that along with the rib height is increased, the rib itself is compressed. Based on the experiments, the article analyses the influence on both increase and compression of rib height by such factors as wall-thickness compression at the bottom of the rib (ε%), wall thickness to diameter ratio(δ0/D0) , plug groove to rib height ratio (K) and friction conditions etc. and relevant relationship.

  • 【被引频次】1
  • 【下载频次】23
节点文献中: 

本文链接的文献网络图示:

本文的引文网络