节点文献

微晶玻璃封包He~3渗漏的检测

Leak Detection of He~3 in the Microcrystal Glass Package

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王国保; 关再亮; 陈文奎;

【Author】 Wang Guobao, Guan Zailiang and Chen Wenkui (Institute of Atomic Energy)

【机构】 中国原子能科学研究院; 中国原子能科学研究院 北京 102413; 北京 102413; 北京 102413;

【摘要】 激光陀螺增益管为玻璃封包的激光器件,内充比例一定的低压强 He3和 Ne混合气 体。He3的渗漏将直接影响增益和寿命.本工作用四极质谱计检测充He3的增益管向 高真空测试系统的渗漏所引起的 M3分压强增高与无增益管时高真空系统内本底的M3 分压强相比较来判定 He3渗漏的有无;并以 He4的标准漏孔作为参考,粗略地估算微 晶玻璃封包材料的增益管的He3渗漏率和渗漏常数。

【Abstract】 A gain tube of laser gyro is a laser device with glass package in which the mixed gasses of Hes and Ne in certain ratio is filled at low pressure. Leak of Hes will directly affect the gain and the lifetime of the device. In this work, leak from the gain tube filled Hes to high vacuum measuring system could be detected by a quadrupole mass spectrometer. which will increase the partial pressure of Mass 3 and compare with the background of partial pressure of Mass 3 in high vacuum system without the gain tube, so that it can be decided whether there is He3 leakage. And with reference to a standard leak for He4, the leak rate and the permeation constant of microcrystal glass used as packing material of the gain tube for He3 could be roughly estimated.

【关键词】 四极质谱计; He3; 渗漏; 检测;
  • 【被引频次】1