ESTIMATION OF FIXED BED HEAT TRANSFER PARAMETERS WITH ORTHOGONAL COLLOCATION

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈裕中陈锦文王金波

【Author】 Chen Yuzhong Chen Jinwen Wang Jinbo (Tianjin University,Tianjin)

【机构】 Tianjin University TianjinTianjin UniversityTianjin

【摘要】 <正> Two heat transfer parameters in the fixed bed,radial effective conductiviw ker,and wall heat transfer coefficient hware estimated by using the method of orthogonal collocation and non-linear least square.The temperatures at forty collo-cation points distributed along the radial direction are measured simultaneously by means of multiehannel data logger.Theeffects of bed height,Rep,dt/dp,gas inlet temperature and wall temperature on kerand hw are studied.The results indicatethat the effect of gas inlet temperature and wall temperature is negligible.Bed height will only influence the parameter es-timations in shallow bed and at low Rep.Both kerand hw tend to reach a limit with increasing bed height.The asymptoticbed height which is independent of dp is about 0.5 m,while the asymptotic values of kerand hw increase with dp.The pa-rameters obtained with the wall being heated are about 10% lower than those with the wall being cooled.ker,hw and stag-nant contribution terms kerand hw are all related to dp·kerand hw estimated at the asymptotic bed height are correlated bythe following equations:ker=0.199+0.015 dt/dp+0.0020/(1+14.15(dp/dt2)Rephw=33.4+4.23dt/dp+0.333/(1+8.54(dp/dt2)Rep(5.5<dt/dp<13)(100<Rep<500)

【Abstract】 Two heat transfer parameters in the fixed bed,radial effective conductiviw ker,and wall heat transfer coefficient hw are estimated by using the method of orthogonal collocation and non-linear least square.The temperatures at forty collo- cation points distributed along the radial direction are measured simultaneously by means of multiehannel data logger.The effects of bed height,Rep,dt/dp,gas inlet temperature and wall temperature on kerand hw are studied.The results indicate that the effect of gas inlet temperature and wall temperature is negligible.Bed height will only influence the parameter es- timations in shallow bed and at low Rep.Both kerand hw tend to reach a limit with increasing bed height.The asymptotic bed height which is independent of dp is about 0.5 m,while the asymptotic values of kerand hw increase with dp.The pa- rameters obtained with the wall being heated are about 10% lower than those with the wall being cooled.ker,hw and stag- nant contribution terms kerand hw are all related to dp·kerand hw estimated at the asymptotic bed height are correlated by the following equations: ker=0.199+0.015 dt/dp+0.0020/(1+14.15(dp/dt2)Rep hw=33.4+4.23dt/dp+0.333/(1+8.54(dp/dt2)Rep (5.5<dt/dp<13)(100<Rep<500)

【关键词】 inletnegligibleasymptoticcollocationloggerradialshallowcooledoutletheated
  • 【文献出处】 Journal of Chemical Industry and Engineering ,化工学报(英文版) , 编辑部邮箱 ,1990年02期
  • 【下载频次】11
节点文献中: 

本文链接的文献网络图示:

本文的引文网络