用探极-光谱法诊断扁平氦氖激光器放电等离子体电子温度
Diagnosis of electron temperature of discharge plasma in flat He-Ne lasers by the probe-spectrometry method
【摘要】 用探极-光谱诊断技术,量测扁平氦氖激光器内放电等离子体的电子温度,阐明了诊断原理。实验量测表明,扁平放电截面氦氖激光管内等离子体电子温度基本上与直径为其短边长度的1.5倍园截面放电等离子体电子温度相当。
【Abstract】 The electron temperature of discharge plasma in flat He-Ne laser is di-agnosed by the probe-spectremetry method, and the principle of this kind of diagno-stic technigue is explained. It is indiented from experiments that the electron temper-ature in He-Ne laster tube having flat cross -section is approximately equal to that having circular cross- section in which its diameter is 1.7 timos as large as the length of short side of flat cross-section.
【基金】 国家自然科学基金委员会资助项目
- 【文献出处】 激光杂志 ,Laser Journal , 编辑部邮箱 ,1990年03期