节点文献

荧光素汞—硫—铜—乙醇体系荧光光度法测定痕量铜

Fluorimelric Determination of Trace Copper with Fluoresceinmercury-Sulfide-Copper-Ethanol system

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 司志坤; 朱贵云; 杨景和; 陈国光;

【Author】 Si Zhikun,Zhu Guiyun,Yang Jinghe,Chen Guoguang (Department of Chemistry, Shaadong University)

【机构】 山东大学化学系; 山东大学化学系 济南; 济南; 济南;

【摘要】 本文利用Cu2+与荧光素汞—硫络合物中硫反应,从而释放出荧光素汞,使荧光强度增加的原理,提出了测定铜的荧光光度法。实验表明,0.1MNaOH中,无水乙醇增敏作用下,Cu2+在10×10-6—1.0×10-9M范围内与荧光强度有良好的线性关系。最低检测限为2×10-10M,该方法操作简便,灵敏度高,用多点增量标准加入法测定地质矿样中的铜,结果令人满意。

【Abstract】 In present paper,an indirect lluorimetric method for the determination of trace copper,based oa the reaction with iluoresceinmercuric sulfide enhancing fluorescence in 0.1M sodium hydroxide solution was studied. Test showed that alcohol can enhance the fluorescence of the system. The fluorescence intensity is measured at 520 nm with a excited wavelength 499nm, it is a linear function of the concentration in the range of 1.0×10-3-1.0×10-9M for cooper. The detection limit is 1.3×10-8g/1(13ppt) This method has been used for the determination of copper in a real sample and water with satisfactory results.

  • 【文献出处】 冶金分析 ,Metallurgical Analysis , 编辑部邮箱 ,1989年05期
  • 【被引频次】2
  • 【下载频次】42
节点文献中: 

本文链接的文献网络图示:

本文的引文网络