节点文献

高压消化-金电极阳极溶出伏安法测定人体中痕量硒

Determination of Trace Selenium in Human Body by Anodic Stripping Voltammetry at Gold-disc Electrode

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 乔文建; 李金芳; 王瑞彬;

【Author】 Qiao Wenjian, Li Jinfang, Wang Ruibin Department of Chemistry, Faculty of Basic Medical Sciences, Tongji Medical University, Wuhan Laboratory of Chemical Analysis, Research Center of Experimental Medicine

【机构】 同济医科大学基础医学部化学教研室; 同济医科大学基础医学部实验医学研究中心分析测试室; 同济医科大学基础医学部化学教研室;

【摘要】 我们用高压溶样器做人体样品预处理,有效防止了样品消化过程中硒的挥发损失;用金电极阳极溶出伏安技术研究了人体中痕量硒的测定方法,确定了最佳测试条件,检出下限为2×10-8g/L。实测人体样品,硒的回收率为96.6±6.7%(+SD),变异系数CV为7.0%。

【Abstract】 We used High-pressure Wet Digester to pretreat the samples that were got from the human body. This method is very effective in preventing the selenium from undergoing volatilization that often occurs in the sample pretreatment,so the selenium loss is very little. We have studied the method of using anodic stripping vol-tammetry at gold-disc electrode to determine the trace selenium existing in the human body, where we found the best experimental condition for determining the trace selenium after a series of experiments. The detection limit is about 2×10-8g/L. Recovery of selenium is about 96.6±6.7% (X±SD), and the variant coefficient,CV=7.0%.

【关键词】 硒; 金电极; 脉冲极谱;
【Key words】 selenium; gold-disc electrode; pulse-polarography;
【基金】 国家自然科学基金
  • 【文献出处】 同济医科大学学报 ,Journal of Tongji Medical University , 编辑部邮箱 ,1989年03期
  • 【下载频次】40
节点文献中: 

本文链接的文献网络图示:

本文的引文网络