节点文献

哈氏棒断棒原因及防断措施

THE REASON AND PROPHYLAXIS FOR THE BREAKAGE OF HARRINGTON DISTRACTION ROD

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 朱孝华; 胡瑞娟; 洪天禄; 唐天驷;

【Author】 Zhu Xiaohua (Physics Department)Hu Ruijuan (Suzhou Polytechnic Institute of Silk)Hong Tianlu Tang Tiansi (Suzhou Medical College)

【机构】 苏州大学物理系; 苏州丝绸工学院; 苏州医学院; 苏州医学院;

【摘要】 哈林顿分离棒(哈氏棒)应用于脊柱侧凸和胸腰椎骨折临床治疗,矫形治疗效果显著.然而,其并发症发病率约为4. 5%,断棒时有发生.文章分析了断棒原因,提出了附加保护套简作为防断的切实可行方法.

【Abstract】 Harrington distraction rod has been used in clinical practicefor scoliosis and fractures of the thoracolumbar spine.The result of correct-ing spinal deformities is satisfactory.However,the incidence of the complica-tion following Harrington instrumentation is 4. 5%.One of the complicationis the breakage of Harrington rod.The reasons of the breakage of Harringtonrod are analysed.Theauthors recommend to attach a casing pipe as a reliablemethod for prophylaxis of the breakage of Harrington rod.

  • 【文献出处】 苏州大学学报(自然科学) ,JOURNAL OF SUZHOU UNIVERSITY , 编辑部邮箱 ,1989年01期
  • 【下载频次】30
节点文献中: 

本文链接的文献网络图示:

本文的引文网络