丝质外科缝合线的辐射灭菌和材质损伤的研究
A STUDY ON RADIATION STERILIZATTON AND RADIATION DAMAGE FOR SURGICAL SUTURE
【摘要】 本文报道了外科用丝质缝合线的电子束和γ射线灭菌的效应,测定了初始污染程度和D10值的分布。此外,对辐照后材质性能也进行了理化分析,测试了拉伸强度、溶出物、OD值和溶出液的紫外吸收谱等。从而比较了两者的辐射灭菌效应和对材质的影响。
【Abstract】 The effect of Electron Beam and γ ray sterilization for silk surgi-cal suture was studied. The initial contamination and distribution of D10 value weremeasured. Physical and chemical analysis of the material, such as tensile strength.water soluble extractive matter, optical density and U V spectrum were made afterirradiation. In addition, a comparsion of material degradation between E B and γ ste-rilization was investigated.
【关键词】 辐射灭菌;
指标菌;
短小芽胞杆菌;
D10值;
初始污染;
灭菌保证水平;
【Key words】 Radiation sterilization; Indicative bacteria; Bacillus pumilus; Initial contamination; Decimal reduction value; Sterility assurance level;
【Key words】 Radiation sterilization; Indicative bacteria; Bacillus pumilus; Initial contamination; Decimal reduction value; Sterility assurance level;