半导体γ谱仪对环境样品全能峰效率的半经验公式刻度方法
DETECTION EFFICIENCY CALIBRATION OF A SEMICONDUCTOR γ-SPECTROMETER FOR ENVIRONMENTAL SAMPLES
【摘要】 本文报道了用半经验公式对φ5.3×5.7cm 高纯锗γ谱仪对环境样品的全能峰效率进行刻度的方法和结果。制备了以土壤、煤、矸石为介质的不同厚度的φ7.5cm 的圆柱形137Cs、Ra-系和 Th-系标准参考源,对本方法进行了验证。本方法的结果与标准参考源的参考值基本上在7.1%以内符合。
【Abstract】 A semi-empirical formula was adopted to calibrate an HPGe γ-spectrometer for its full energy peak efficiency to environmental samples.The procedure of calibration was discribed,and the resultsWere compared with those obtained through a set of reference souces of 137Cs,226Ra-series and 232Th-series,which were made up withmediums of soil,coal and stone-coal.It was found that the bothresults were consistent within 7.1%.
【关键词】 高纯锗γ谱仪;
全能峰效率;
环境样品;
刻度;
【Key words】 HPGeγ-spectfometer; Full Energy Peak Efficency; Environmental Sample; CaLibration;
【Key words】 HPGeγ-spectfometer; Full Energy Peak Efficency; Environmental Sample; CaLibration;
- 【文献出处】 辐射防护 ,Radialization Protection , 编辑部邮箱 ,1989年03期
- 【被引频次】2
- 【下载频次】82