节点文献

自制“茎突分离保护器”及茎突过长症的治疗应用

SELF-MADE SEPARATE AND PROTECTIVE APPARATUS FOR PROCESSUS STYLOIDEUS AND IT’S CLINICAL APPLICATION

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 赵连城

【Author】 Zhao Liancheng (Dept of Otorhinolarynogology, The First Affiliated Hospital)

【机构】 中国医科大学附属第一医院耳鼻咽喉科

【摘要】 本文介绍了自制“茎突分离保护器”的质地、规格、性能。茎突截短术应用代用器械手术18例,每侧截除长度平均为1.75cm;应用自制器械30例,每侧平均截除长度为2.52cm,且比代用器械每侧可缩短手术时间30~40分钟。文章还评价了包括颈外切开的6例,共54例手术的疗效。

【Abstract】 The main treatment method of "Processus Styloideus Syndrome" is to cut short the over-growth processus styloideus. Never before has special apparatus been used. The curette for sinus ethmoid and other substittute instruments were often used. Because the operation field is deep and narrow, when using substitute apparatus, it is not easy to expose proccssus sufficienfly, and the operation is quite difficult. The application of the self-made"separate and protcctive apparatus of processus styloideus" made it easier to find the processus styloideus, and avoid the disadvantage of substitute apparatus. This article reports 54 cases operative curative effect. Using substitute apparatus, the everage cutting length of processus for every side was 1.75cm.With the"separat and protective apparatus of processus styloideus’, it was 2.52cm. The time for operation 30-40 minutes shorter than the former. The total operative effective rate of this group was 77.8%

【关键词】 茎突综合征茎突过长症
【Key words】 Processus styloideus syndromeApparatus