节点文献
高钛渣中低价钛测定方法的研究
STUDY ON THE METHOD FOR DETERMINATION OF TITANIUM(Ⅱ, Ⅲ) IN HIGH-TITANIUM SLAG
【摘要】 本文对高钛渣中TiO,Ti2O3测定的方法进行了研究。首先采用HNO3+H2O2浸取,以与M·Fe,TiC,TiN,FeS等分离,再用HCl浸取钛铁矿及残留的M·Fe,FeS及少量Fe2O3等,残渣中TiO,Ti2O3在CO2气体保护下,用HCl+HF溶解,在溶前及溶后加Fe3+标液于上述体系中,以氧化低价的钛,剩余的Fe3+标液以TiCl3标液滴定,根据Fe3+标液消耗的差值,计算出Ti2+,Ti3+,换算成TiO,Ti2O3的百分含量。根据岩相鉴定,所拟定的方法是可靠的,其分析周期较短,符合工艺流程规律的要求。方法的相对误差,当Ti2++Ti3+=9.87%时为4.89%。
【Abstract】 A method for determination of TiO, Ti2O3 in high-Titanium slag has been proposed. The slag is treated by HNO3-H2O2 to dissolve M·Fe, TiC, TiN, FeS etc, and then treated by HCl to further dissolve FeO-TiO2, M·Fe, FeS and a little Fe2O3 in residue. The remainder TiO and Ti2O3 are dissolved by HCl-HF under the protection of CO2. Standard Fe3+ solution is added into the mentioned system before and after treatment by HCl-HF to oxidize Ti2+ and Ti3+. The excess Fe3+ is titrated by standard TiCl3 solution. The content of TiO and Ti2O3 can be calculated from the volume difference of standard TiCl3 solution consumed by Fe3+. The selective dissolution effect is supported by microscope observation. The established method can satisfy the demand of technological process with short analysis period. It’s relative error is 4.89% at Ti2++Ti3+=9.87%.
- 【文献出处】 理化检验.化学分册 ,Physical Testing and Chemical Analysis(Part B:Chemical Analysis) , 编辑部邮箱 ,1988年01期
- 【分类号】O655.2
- 【下载频次】18