【摘要】 通过模拟试验和数值计算,本文阐述了110~220kV变电所中由于电磁式电压互感器引起的谐振过电压的主要特性,指出了常规限制方法的可能性和局限性,提出了新的稳压消谐方法,借以强迫性地限制端部电压和吸收谐振能量。研究表明,此法是十分有效的。
【Abstract】 This paper, based on model experiment and numerical computation, presents the principal characteristics of ferroresonance developed by electromagnetic voltage transformer, points out the possibility and the limitations of conventional methods of restriction on overvoltage, and provides a new method of suppressing the ferroresonance by means of voltage stabilizer for the purpose of forced fixing the terminal voltage and absorbing the resonance energy. The detailed study shows that this method is quite effective.