在停炉过程中使用联氨-氨液热钝化的保养方法
Protection of Boilers Off Load by Hot Passivation with Hydrazine/Ammonia Solution
【摘要】 本文根据实验室试验结果和现场应用实例,说明在停炉过程中利用锅炉余热,以联氨-氨溶液使金属表面钝化,是停炉保养的一种有效方法。该方法特别适用于锅炉检修时的保养。
【Abstract】 Based on the experimental results and the field operating experience,this paper in-troduces the method of protecting boilers off load by passivating the metal surfaces whi-lst hot with a solution of hydrazine and ammonia.This method is found to be effectiveand particularly suitable for boilers shut down for maintenance.
- 【文献出处】 电力技术 , 编辑部邮箱 ,1985年12期
- 【被引频次】1