【摘要】 本文报道在IgM-抗HBc测定(固相酶标记双抗体法)中,应用抗 HBc-IgGF(ab′)2段制备的酶结合物,能完全去除类风湿因子(RF)所致的假阳性反应(0/10),较加用阴性血清、凝聚IgG 等方法显著为优。文中简述了制备的方法。
【Abstract】 In order to keep the specificity and reliability of the detection of IgM-anti-HBc byELISA,the interference of rheumatoid factor(RF)should be eliminated.We foundthat the interference of RF was completely removed by using enzyme-labeledF(ab′)2fragments from IgG-antibodies against the HBc.With anti-HBc-IgG conjugate contain-ing 10% anti-HBc negative serum,the interference of RF was obviously suppressed,but not completely eliminated.The method of adding agglutinative IgG(anti-HBc ne-gative)to samples and conjugate(containing 0.1-5 mg/ml),the false positive reactiondue to RF could not be effectively eliminated.