节点文献
感应读出式自猝灭流光计数器
INDUCED READOUT SELF-QUENCHING STREAMER COUNTER
【摘要】 本文介绍了自猝灭流光计数器的新技术——具有阻性阴极的感应读出式自猝灭流光计数器的特点及初步实验结果。用不同比例的Ar/C4H10、Ar/CH4或Ar/CO2作为基本工作气体,研究了阳极丝直径、电子学死时间等对计数率坪曲线的影响;研究了几种不同的猝灭剂(H2C(OCH3)2、C2H5OH、C6H6、C7H12含量与坪曲线的关系;也测量了该计数器的探测效率和死时间。
【Abstract】 In this paper, a new technology about self-quenching streamer counter—induced readout with resistive cathode, some characteristics and preliminary results are introduced. We have investigated the influence of wire diameter, dead time on plateau curves, using different gas mixture filled in the tube (Ar/C4 H10, Ar/CH4 and Ar/Co2) as basic working gas. The relations between content of various quenchers (H2C(OCH3)2, C2H5OH, C6H6 and C7H12), plateau curves and the efficiency ane dead time of the tube were measured.
- 【文献出处】 高能物理与核物理 ,High Energy Physics and Unclear Physics , 编辑部邮箱 ,1985年04期
- 【被引频次】2