关于木材蒸汽干燥室凝结水总管计算公式的探讨
DISCUSSION ON THE CALCULATION FORMULA OF THE GENERAL PIPES FOR CONDENSATION WATER IN THE WOOD STEAM DRY ROOM
【摘要】 <正> 目前,在木材蒸汽干燥室工艺设计中,凝结水输送总管直径均按下列公式计算(1): d水=(1.27q最大/3600γ水ω水)1/2米 (1)式中:q量大——最大蒸汽消耗最(公斤/小时); γ水——凝结水的容重,取值960(公斤/米3); ω水——凝结水在管内的流动速度,取0.5—1(米/秒)。 在实践中曾碰到二个问题:第一,与暖通专业在确定高压回水管的计算方法不同,
【Abstract】 The calculation of the high pressure condensation water pipes is an irrevocable problem in engineering design. In the light of the practice of engineering design in the wood steam dry room, this paper puts forward an exploratory opinion on the calculation of diameter of the high pressure condensation water pipes. Furthermore, from the viewpoint of speciality9 this paper derives a new calculation formula theoretically.
- 【文献出处】 东北林业大学学报 ,Journal of Northeast Forestry University , 编辑部邮箱 ,1985年04期