右心导管测定大鼠肺动脉压的实验方法

Method for Measuring Pulmonary Artery Pressure by Right Cardiac Catheter in Rats

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 孙波刘文利

【Author】 Sun Pa and Liu Wenli(Institute of Basic Medical Sciences, Beijing)

【机构】 基础医学研究所生理室基础医学研究所生理室 北京北京

【摘要】 <正> 目前,临床上测定肺动脉压一般采用右心导管法。人及大动物的右心导管检查可用漂浮导管术,但对小动物,即使最小号的漂浮导管也仍嫌太大。国内有用自制软塑料管施行家兔右心导管术者,但象大

【Abstract】 A method for measuring pulmonary artery pressure (PAP) by right cardiac cathter in rats was reported. A 13cm long polyethylene tube(OD 0.9mm) with timing tip was used as the cardiac catheter.In general, it takes about 3-15 minutes to manipulate the catheter from the right external jugular vein into tbe pulmoary artery without any introducer. The percentage of success is more than 95%.The mean PAP measured in 30 normal rats is 19.1 ± 0.4mmHg.The average systolic and diastolic pressures are 23.2 ±0.7 and 15.0± 0.5mmHg respectively.These data are similar to that reported in literature.

  • 【文献出处】 中国医学科学院学报 ,Acta Academiae Medicinae Sinicae , 编辑部邮箱 ,1984年06期