玻璃碳电极同位镀汞阳极溶出伏安法同时测定铜、铅、镉、锌的可能性
Possibility of the Simultaneous Determination of Cu,Pb,Cd,Zn by Anodic stripping voltammetry With a Glassy Carbon Electrode Mercury-Plated in situ
【摘要】 本文用线性扫描阳极溶出伏安法(ASV)和微分脉冲阳极溶出伏安法(DPS)研究了在同位镀汞玻璃碳电极上同时测定铜、铅、镉、锌的可能性。实验证明同时测定这些离子的困难在于汞齐中形成金属间的化合物;干扰主要取决于铜和辞在汞齐中的相互作用;对一般未污染的环境样品用ASV或DPS同时测定铜、铅、镉或锌、铅、镉不会产生固难;用ASV同时测定铜、铅、镉、锌时在铜的溶出峰前出现一个铜辞化合物中辞的溶出峰,按本文所提出的测量峰电流的方法可以同时测定上述四种离子;用DPS可以用较短的富集时间同时测定这些离子。所制定的方法应用于鉴定蒸馏水及饮用水质量发现,由电加热蒸馏水器得到的蒸馏水会带来铜、铅的污染;济南地区各自来水厂水源中上述离子的含量大大低于国家规定的生活饮用水质标准。
【Abstract】 Possibility of the simultaneous determination of trace metals (Cu, Pb, Cd, Zn) by both anodic stripping voltammetry (ASV) and differential pulse anodic stripping voltammetry (DPS) at a rotatable glassy carbon electrode coated in situ with a thin mercury film was studied. Experimental results showed that the difficulty of simultaneous determination of those metals was connected with the formation of intermetallic compound in amalgam, in particular with the interaction of Zn and Cu. It is not difficult to determine simultaneously Cu, Pb and Cd or Zn, Pb and Cd in non—polluted enviromental samples. For the solution with Cu2+, Zn2+, Cd2+ , Pb2+ a new peak before Cu peak is displayed when ASV is used.It is a stripping peak of Zn in ZnxCuy. Nonetheless it is possible to determine four metals by ASV simultaneously. When DPS is used the deposition time can be shortened.The methode of the simultaneous determination of Cu, Pb, Cd and Zn was applied to examine the quality of distilled water and tap water.
- 【文献出处】 山东大学学报(自然科学版) ,Journal of Shandong University , 编辑部邮箱 ,1984年02期