【摘要】 本文系介绍一种新颖的板波模式的超声雾化送样装置,与国产高频小功率感耦等离子体发生器及平面光栅摄谱仪联用中主要工作参数的折衷选择,同时对25种元素光谱灵敏线的觉察浓度值、记忆效应、基体效应、各种酸的雾效应、雾化效应等实验数据作了分析。
【Abstract】 Compromise selection of several main parameters when using a new type supersonic nebulizer of transverse wave pattern combined with high frequency low power ICP generator and flat grate spectrograph were introduced and experimental data such as visual detect limit of special spectrum line of 25 elements, memory effect, matrix effect, mist effect of some acids in different acidity and nebulizer efficiency were analysed.